Product Overview
Engineered for ultimate cost performance in pneumatic automation systems, the SP-04 Series Dual-Channel Air Pressure Economical Digital Pressure Switch features an innovative dual-channel input architecture capable of both independent dual-point monitoring and differential pressure measurement. By consolidating two pressure switches into a single compact housing, the SP-04 delivers 50% less space occupation, 50% fewer air tubes, 50% less wiring, and a 50% cost reduction. Combined with foolproof operation, flexible pressure range combinations, and optional RS485 communication, it simplifies piping and elevates industrial connectivity.
Product Highlights
Innovative Dual-Channel Input
Functions as a dual-purpose gauge supporting fully independent two-channel air pressure monitoring or precise differential pressure detection in one unit.
50% Space, Wiring & Cost Savings
Drastically simplifies equipment layout by cutting installation footprint, pneumatic tubing, electrical wiring, and procurement cost by half.
Foolproof Operation & RS485 Option
Features a clear 3-color dual-screen display for intuitive, efficient setup, with optional RS485 communication for seamless industrial interconnection.
Model Selection & Technical Framework
To meet diverse dual-point and differential pneumatic control requirements, the SP-04 series offers flexible pressure range combinations, multi-channel outputs, and standardized dual-port interfaces:
| Series Designation |
04 Base Platform (SP-04): Dual-channel Air Pressure Economical Type digital pressure switch with 3-color (Red/Orange/Yellow-Green) display and ISO 8573-1:2010 [7:4:4] non-corrosive gas compatibility. |
| Input Pressure Spans |
PP Code (Dual High-Pressure): 2-channel high-pressure input (-0.101 to 1.000 MPa; Max withstand: 1.5 MPa). PC Code (Hybrid Input): 1-channel high-pressure (-0.101 to 1.000 MPa) + 1-channel low-pressure (-101.3 to 101.3 kPa). CC Code (Dual Low-Pressure): 2-channel low-pressure input (-101.3 to 101.3 kPa; Max withstand: 500 kPa). |
| Output Signal Options |
3-Channel Switching (130 / 230): 3-channel NPN open collector output (130) or 3-channel PNP open collector output (230). RS485 Communication (113 / 213): 1-channel NPN output + 1 set of RS485 communication (113), or 1-channel PNP output + 1 set of RS485 communication (213). |
| Port & Fitting Interfaces |
MM Interface: Dual air nozzle fitting with female M5 thread, compatible with optional Ø4mm / Ø6mm barbed or quick screw fittings. |
| Core Electrical & Performance Specs |
Power Supply: 12~24V DC ±10% (Current consumption < 45mA no load). Accuracy & Repeatability: Display accuracy ±2% F.S. ±1 digit (25±3°C); Repeatability ±0.2% F.S. ±2 digits. Response Time & Enclosure: Selectable from 2.0ms up to 5000ms; IP40 protection grade; Operating temp 0~50°C. |
Mounting Methods & Optional Accessories
Accessory Models (Optional, Separate Order Required):
- • XP-BT-04: L-type metal mounting bracket.
- • XP-BT-05: Z-type metal mounting bracket.
- • XP-PA-01: Panel mounting bracket (supports compact installation & protective cover).
- • XP-BT4-M5 / XP-BT6-M5: Barbed fitting, internal M5 for Ø4mm / Ø6mm air tube.
- • XP-KN4-M5 / XP-KN6-M5: Quick screw fitting, internal M5 for Ø4mm / Ø6mm air tube.
Comprehensive Application Scenarios
With dual independent pressure sensing and differential calculation capabilities, the SP-04 series adapts seamlessly to a wide range of pneumatic monitoring and diagnostic setups:
Air Filter Clogging Detection Monitors compressed air filter status in real time by detecting the differential pressure between high-pressure and low-pressure channels.
Pipeline Leakage Detection Compares test objects against a reference standard to accurately identify air leaks via subtle pipeline differential pressure changes.
Pipeline Filter Air Monitoring Tracks airflow resistance across ducted and pipeline filter assemblies to schedule timely maintenance before pressure drops occur.
Dual-Purpose Independent Gauge Replaces two separate switches by monitoring two completely independent air pressure lines simultaneously in compact machinery.
Frequently Asked Questions (FAQ)
Q: Can the SP-04 measure both independent pressures and differential pressure?
A: Yes. The SP-04 features an innovative dual-channel input design that allows it to monitor two separate air lines independently or calculate differential pressure for filter clogging and leak testing.
Q: What pressure range combinations are available for the dual channels?
A: You can choose from three configurations: PP (two high-pressure channels, -0.101~1.000 MPa), CC (two low-pressure channels, -101.3~101.3 kPa), or PC (one high-pressure channel paired with one low-pressure channel).
Q: Does the SP-04 support industrial communication and panel mounting?
A: Yes. Output codes 113 and 213 provide 1-channel NPN/PNP switch output paired with RS485 communication. For installation, optional XP-BT-04 (L-type), XP-BT-05 (Z-type), and XP-PA-01 panel brackets are available for separate order.
Company Advantages & Factory Strength